#Error codes
Each validation problem has a JSON path, a code, and a localized message.
#Scenario validation
| Code | Meaning |
|---|---|
type |
Wrong value type. |
required |
Missing required field or parameter. |
unknown-field |
Unknown format-2 field or behavior parameter. |
enum |
Value outside the allowed choices. |
range |
Number outside its allowed range. |
version |
Unsupported formatVersion. |
id |
Invalid identifier syntax. |
address |
Malformed or out-of-range individual, line, or group address. |
duplicate |
Duplicate identifier or address. |
reference |
Reference to a missing line, channel, object, coupler, or topology level. |
port |
Port not accepted by a behavior, or an invalid channel association. |
dpt |
Unsupported DPT or DPT incompatible with a port. |
association |
Incompatible payload sizes on one group address. |
no-ga |
A control action refers to an object without a group address. |
toggle |
"toggle" used with an object that is not one bit. |
conflict |
Mutually incompatible actions or topology settings. |
incompatible |
Button, input, or equipment incompatible with its behavior. |
unknown-behavior |
Behavior ID has not been registered. |
unknown-equipment |
Equipment type has not been registered. |
unknown-room |
Referenced room is not declared in rooms. |
format |
A text value does not have the expected format, such as clock.start. |
#During simulation
| Code | Meaning |
|---|---|
extension-error |
An extension threw an exception; the simulation pauses. |
cascade |
Too many events occurred at the same simulated time. |
incompatible-command |
Equipment cannot apply a behavior's output command. |
no-ga |
A send was requested for an object without a group address and was ignored. |
view-error |
An equipment view failed; a warning frame replaces it while simulation continues. |
#Configuration warnings
These warnings do not stop the simulation. They are shown above the diagram, and in getState().diagnostics, when a parameter that compensates a property of the load disagrees with that property. A scenario can keep such a mismatch on purpose to illustrate a commissioning error.
| Code | Meaning |
|---|---|
config-valve |
The heating actuator output (valveType) and the connected radiator valve (normallyOpen) disagree; the valve opens when no heat is requested. |
config-wiring |
The shutter actuator output inversion (invertOutput) and the motor wiring of the shutter (wiringReversed) disagree; the shutter moves opposite to the commands. |
config-contact |
The window contact type (contactType) and the input inversion (invert) disagree; open and closed are reported the wrong way round. |
config-datatype |
A group address links DPTs of the same size but different meaning, such as a scene number (17.001) and a percentage (5.001), or 5.001 and 5.004. One-bit DPTs are not compared. |
config-polarity |
A group address links DPT 1.009 (1 = closed) and DPT 1.019 (1 = open), whose values have opposite meanings. |